SRVO-214, SRVO-213, SRVO-217, SRVO-219, SRVO-220 and more: find your alarm, see exactly which fuse blew and where it sits on the board, with original diagrams, ratings and FANUC part numbers for R-30iB, R-30iB Plus and R-30iB Mate / Mate Plus controllers.
A blown fuse inside a FANUC robot controller almost always announces itself in one of two ways: a specific alarm on the teach pendant, or one specific thing that suddenly stops working. This page connects each of those symptoms to the exact fuse behind it: which board it sits on, where that board lives in the cabinet, where the fuse is on the board, its rating, and its FANUC part number.
It covers the R-30iB, R-30iB Plus (A-cabinet and B-cabinet) and R-30iB Mate / Mate Plus controllers, with the fuse alarms of the Compact Plus and Mini Plus (CRX) as a bonus. Every board drawing is an original Xpert Robotics diagram with the fuse in question highlighted in yellow. Tap a drawing to open it full-size.
Warning: A controller holds mains voltage and stored energy even when switched off. Read Safety first before you open the cabinet.
This guide is a starting point, not a replacement for the FANUC manual. Always confirm the fuse, its position, rating and part number in the official FANUC maintenance manual for your controller before you work on it. Xpert Robotics accepts no liability for errors on this page or for how it is used: see the full disclaimer.
Find your alarm
Type the alarm number from the pendant (for example 214) or a symptom, or filter by controller, then tap the card. Every section has its own link: use the link button next to a heading to send it to whoever is standing at the robot. "Mate" means R-30iB Mate and Mate Plus unless a card says otherwise.
18 of 18
- SRVO-2146ch amplifier fuse blownCheck
FS2/FS36-axis servo amplifier · R-30iB / Plus and Mate / Mate Plus - SRVO-213E-STOP Board FUSE2 blownCheck
FUSE2E-stop board · R-30iB / Plus - SRVO-007External emergency stopsCheck
FUSE2E-stop board · Mate / Mate Plus - SRVO-217 · PRIO-091E-STOP Board not found · E-Stop PCB comm errorCheck
FUSE1/F3E-stop board / PSU · R-30iB / Plus - SRVO-220SDI fuse blownCheck
FUSE1Main board · Mate / Mate Plus - SRVO-219Safety I/O brd fuse1 / fuse2 blownCheck
FU1/FU2Safety I/O board · R-30iB / Plus and Mate / Mate Plus - SRVO-348DCS MCC OFF alarmCheck
FUSE4E-stop board · R-30iB / Plus B-cabinet - SRVO-057 · SRVO-058FSSB disconnect / init error, all amplifier LEDs darkCheck
F4first (R-30iB / Plus), thenFS1PSU, then servo amplifier · R-30iB / Plus and Mate / Mate Plus - PRIO-093Fuse blown (Rack, Slot)Check
FUSE1Process I/O board · R-30iB / Plus and Mate / Mate Plus - SRVO-215Brake Unit fuse blownCheckBrake unit fuseAux-axis brake unit · Any controller with the aux-axis brake option
- SRVO-227 · SRVO-228 · SRVO-229Amplifier / RI/O / SDI fuse blownCheck
FUSE9/FUSE4/FUSE2Main board / interface unit · Compact Plus, Mini Plus - No alarmTeach pendant screen darkCheck
FUSE3; Mate / Mate Plus alsoFUSE5; Mate PlusFUSE8E-stop board · R-30iB / Plus, Mate / Mate Plus (Compact Plus / Mini Plus: other fuses, see details) - No alarmController will not power onCheck
F1/F2PSU / AC reactor · R-30iB / Plus - No alarmPower cuts out right after power-onCheck
F4PSU · R-30iB / Plus - No alarmVision camera has no powerCheck
FU1/FUSE9Main board · R-30iB Plus, Mate Plus - No alarmA cabinet fan stoppedCheck
FUSE6/FUSE7E-stop board · Mate / Mate Plus - No alarmRed LED on the E-stop boardCheck
FUSE2toFUSE5E-stop board · Mate / Mate Plus - No alarmRed FUSE LED on the cobot sensor unitCheck
FUSESensor I/F unit · CR cobots
How to use this page
Four steps
- Read the alarm exactly. Open the alarm screen (MENU → ALARM, then HIST for the history) and note the code, the text and anything in brackets. In
SRVO-214 6ch amplifier fuse blown (R:1), theR:1tells you which servo amplifier. - Know your controller. Check the nameplate: R-30iB or R-30iB Plus (in an A-cabinet or the larger B-cabinet), or R-30iB Mate / Mate Plus. The same fuse can sit in a different place on each.
- Jump to the alarm. Each section shows the fuse highlighted on its board, with its rating and part number, and what to check before you replace it.
- Fix the cause, then the fuse. A fuse that blew once will blow again if the short is still there.
Safety first: read before you open the cabinet
A robot controller holds mains voltage and stored DC energy. Only a qualified electrical technician should open it. If you are not sure, stop and contact us: a wrong fuse, or a wire bridged across a fuse holder, can destroy a board worth far more than a service visit, or silently disable a safety circuit.
Before you touch anything
- Isolate upstream, lock and tag. Switching off the controller's own breaker is not isolation: its input terminals and the incoming supply cable stay live. Lock out the disconnect that feeds the controller. Several fuses on this page sit on the AC side (PSU
F1, AC-reactorF2, Mate / Mate PlusFUSE6/FUSE7, Mate PlusFUSE8, Mini Plus input boardFUSE1): prove zero volts at the fuse holder itself before you touch them. - Servo amplifier: wait for V4. Before touching the 6-axis amplifier, the
V4LED must be off, and a DC voltmeter on the screw just right ofV4must read below 50 V. If the LED is lit or the DC link is 50 V or more, do not touch the amplifier or its cables. This check covers the amplifier only, not the rest of the cabinet. - ESD. Wear a grounded wrist strap and hold boards by their edges.
- Same part, same rating. Replace a fuse only with the same FANUC part number, or at minimum the identical rating and type. Never fit a higher rating.
- Never bypass. Never bridge a fuse with wire, and never jumper an E-stop, fence or safety circuit to "test" the robot.
- Find the short first. A fuse blows for a reason. Fit a new one without finding it and it blows again, or the fault moves upstream to something more expensive.
- Back up before swapping boards. Before replacing a main board or an E-stop unit, take a full controller backup (an image backup where possible).
Fuse alarms, one by one
Fuse FS2 or FS3 has blown on 6-axis servo amplifier number n (R:1 is the first amplifier). Both are 3.2 A fuses on the amplifier's control board. The alarms that appear together with SRVO-214 tell you which one:
Which fuse?
- With SRVO-006 Hand broken and SRVO-005 Robot overtravel: it is
FS2. FS2 feeds the 24 V that goes up the robot to the end effector, plus the hand-broken (XHBK) and overtravel (XROT) signals, so when it blows those two alarms come with it. - With SRVO-043 DCAL alarm: it is
FS3, which feeds 24 V to the regenerative (discharge) resistor. - With neither, and an auxiliary axis on the system: check the setup before the hardware. SRVO-214 also appears when an axis driven by an auxiliary (αiSV) amplifier is set to amplifier type 1 (6-axis amplifier) instead of 2.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / Plus and Mate / Mate Plus | FS2 | 3.2 A | A60L-0001-0290#LM32C | Bottom of the column |
| R-30iB / Plus and Mate / Mate Plus | FS3 | 3.2 A | A60L-0001-0290#LM32C | Middle of the column, between FS1 and FS2 |
FS1 on top, FS3 in the middle, FS2 at the bottom. FS3 being in the middle catches people out.Where the amplifier is: on the left of the back panel in an A-cabinet, in the upper right of a B-cabinet, and in the centre of the back panel in a Mate. See the cabinet maps.
Before you replace FS2 or FS3
- FS2: look for a ground fault on the end-effector 24 V (+24VF): the gripper or tool wiring, its valves and sensors, and the end-effector connector on the arm. Then check the robot connection cable and the cables inside the arm. On an M-3iA, also check the optional fan motor inside the robot.
- FS3: check the regenerative resistor and its cable, and replace the resistor if it is faulty. FANUC also lists a ground fault in an auxiliary-axis amplifier as a possible cause.
- Then replace the fuse. If the new one blows straight away, the fault is still there. FANUC's next step is to replace the amplifier.
FUSE2 on the emergency-stop board protects the +24EXT line: the 24 V that runs out to your external E-stop buttons, fence and door switches, and back. The same alarm also appears when the fuse is fine but there is simply no 24 V between EXT24V and EXT0V, on terminal strip TBOP14 in an A-cabinet or TBOP10 in a B-cabinet. It often arrives together with SRVO-001, SRVO-004 or SRVO-007.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus, A-cabinet | FUSE2 | 1 A | A60L-0001-0290#LM10C | Bottom edge, between CRMB2 and the TBOP14 terminal strip |
| R-30iB / R-30iB Plus, B-cabinet | FUSE2 | 1 A | A60L-0001-0290#LM10C | Left edge, between TBOP11 and TBOP10, above CRMA92 |
FUSE2 is on the bottom edge, between connector CRMB2 and the TBOP14 terminal strip.FUSE2 is on the left edge, between the TBOP11 and TBOP10 terminal strips, above CRMA92.Before you replace FUSE2
- Measure 24 V between
EXT24VandEXT0V. If the cell does not use an external 24 V supply, check the jumpers betweenEXT24VandINT24Vand betweenEXT0VandINT0V. - If FENCE, SVOFF or EXEMG are wired, one of them may be shorted to 0 V or to ground. Check those cables first: a pinched fence-switch cable is a classic cause.
- Still blowing? FANUC's order is: the operator-panel cable (
CRT27), then the E-stop board, then the teach pendant cable, then the pendant itself.
On a Mate / Mate Plus, a blown E-stop FUSE2 usually shows as SRVO-007 with a red 24EXT LED; see SRVO-007. Also, on older Mate, Mate Plus and Compact Plus software (Mate 7DC3/43, 7DC2/33, 7DD0/16 or earlier; Mate Plus and Compact Plus 7DF1/12 or earlier), a blown fuse on the additional safety I/O board is wrongly reported as SRVO-213. If FUSE2 is fine on such a controller, go to SRVO-219.
On a Mate or Mate Plus, if SRVO-007 will not reset even though every external E-stop is released, and the red 24EXT LED on the E-stop board is lit, FUSE2 (the emergency-stop circuit fuse) has blown.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB Mate | FUSE2 | 1 A | A60L-0001-0290#LM10C | Top edge, first from the left, above the 24EXT LED |
| R-30iB Mate Plus | FUSE2 | 1 A | A60L-0001-0290#LM10C | Top edge, first from the left, above the 24EXT LED |
FUSE2 is the first fuse from the left on the top edge, directly above the 24EXT LED. It sits in the same place on the R-30iB Mate board.Before you replace FUSE2
- Measure 24 V between
EXT24VandEXT0VonTBOP19. If no external supply is used, check theEXT24V–INT24VandEXT0V–INT0Vjumpers. - Check the 24EXT emergency-stop wiring for a short or a ground fault.
- Still blowing? Replace the E-stop board, then check the teach pendant.
SRVO-217 E-STOP Board not found · PRIO-091 E-Stop PCB comm error: FUSE1 on the E-stop board, or F3 on the power supply
The main board cannot see the E-stop board. On an R-30iB / R-30iB Plus two fuses cause it: FUSE1 on the E-stop board, which feeds the board's own power-supply circuit, or F3 on the power supply unit, which supplies +24E. This alarm also appears when an additional safe I/O device is missing, so a fuse is likely but not the only cause.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus, A-cabinet | FUSE1 | 1 A | A60L-0001-0290#LM10C | Upper right, just left of CNMC6 and below CRRA12 |
| R-30iB / R-30iB Plus, B-cabinet | FUSE1 | 1 A | A60L-0001-0290#LM10C | Middle of the board, just below FUSE3 |
| R-30iB / R-30iB Plus (A and B cabinet) | F3 | 7.5 A | A60L-0001-0046#7.5 | Mid-height, the upper of the F3 / F4 pair, above the green PIL LED |
FUSE1 is at the upper right, just left of CNMC6 and below CRRA12.FUSE1 is in the middle of the board, just below FUSE3.F3 is the upper fuse of the pair at mid-height, with F4 just below it and the green PIL LED under both.Before you replace FUSE1 or F3
- FUSE1: check the cable between the E-stop board and the main board. If the fuse is fine and the cable is good, FANUC's next steps are the E-stop unit, then (after a full backup) the main board.
- F3: +24E feeds many boards, units and cables in the cabinet. Work through everything on +24E (the power-supply diagram in your maintenance manual lists it) and replace the faulty part. Then replace F3; if it still blows, replace the power supply unit.
FUSE1 on the Mate / Mate Plus main board protects the +24 V the controller supplies to your peripheral I/O (24SDI). The usual cause is 24SDI shorted to 0 V somewhere in the peripheral-device wiring: a pinched cable, a failed sensor, a miswired terminal.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB Mate | FUSE1 | 1.0 A | A60L-0001-0290#LM10 | Connector edge, bottom-left corner of the connector row |
| R-30iB Mate Plus | FUSE1 | 1.0 A | A60L-0001-0290#LM10 | Connector edge, bottom-left corner of the connector row |
FUSE1 is at the bottom-left corner of the connector row; CRS40 is further right, just before the two Ethernet ports.FUSE1 is in the same bottom-left corner. The second fuse in the row, FUSE9, is for vision; see camera has no power.Before you replace FUSE1
- Check the peripheral-device cables for damage and replace any that are faulty.
- Disconnect
CRS40and fit a new fuse. If it still blows with CRS40 disconnected, the fault is on the main board: take a full image backup, then replace the board. - If it only blows with CRS40 connected, FANUC's next suspects are the cable from the E-stop unit to the servo amplifier, the cable from the main board to the E-stop unit, the E-stop unit and the servo amplifier.
A fuse has blown on the optional additional safety I/O board: fuse1 is FU1 (24 V to the safety inputs, SFDI) and fuse2 is FU2 (24 V to the safety outputs, SFDO). When more than one safe I/O device is fitted, the number at the end of the message, such as (1), tells you which device; it matches the DCS Safe I/O device menu.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / Plus and Mate / Mate Plus | FU1 | 1 A | A60L-0001-0290#LM10C | Lower right, left of the JGP connector; the left one of the pair |
| R-30iB / Plus and Mate / Mate Plus | FU2 | 3.2 A | A60L-0001-0290#LM32C | Lower right, between FU1 and the JGP connector |
FU1 and FU2 sit side by side at the lower right, just left of the tall JGP connector. FU1 is the left one.Before you replace FU1 or FU2
- Check the cable on
CRMA90for a ground fault and replace it if needed. That cable carries the safety inputs and outputs these fuses feed. - Replace the fuse. If it blows again, replace the additional safety I/O board.
SRVO-348 means the controller commanded the main contactor (MCC) off and it did not drop out. It has several causes. FANUC's first check is whatever is wired to CRMA74 on the E-stop unit; the second, on an R-30iB / Plus B-cabinet, is FUSE4 on the E-stop board, which protects the SFDI safety inputs. The A-cabinet board has no FUSE4.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus, B-cabinet | FUSE4 | 1 A | A60L-0001-0290#LM10C | Upper left, at the top of the TBOP11 terminal strip |
FUSE4 is at the upper left, at the top of the TBOP11 terminal strip.Before you replace FUSE4
- Check the SFDI wiring and connections for a short, then the operator-panel cable (
CRT27). - Replace the fuse. If it blows again, FANUC's next step is the E-stop unit.
FSSB is the fibre-optic link between the main board and the servo amplifier. FSSB alarms have many causes, but if every LED on the servo amplifier is dark the amplifier has no control power, and there are two fuses to check: F4 on the power supply unit, which FANUC checks first, then FS1 on the amplifier, which generates the amplifier's control-circuit power.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus (A and B cabinet) | F4 | 7.5 A | A60L-0001-0046#7.5 | Mid-height, the lower of the F3 / F4 pair, just above the green PIL LED |
| R-30iB / Plus and Mate / Mate Plus | FS1 | 3.2 A | A60L-0001-0290#LM32C | Top of the fuse column, upper-right edge of the control PCB |
FS1 is the top fuse of the column on the servo amplifier's control board.FS1 is the exception to "fix the cause, replace the fuse". FANUC's instruction for a blown FS1 is to replace the 6-axis servo amplifier, fuse included: FS1 feeds the amplifier's own internal control circuit, so when it blows the fault is almost always inside the amplifier. Contact us for a replacement or repaired unit.
If the amplifier LEDs are lit, FS1 is not your problem. Check the fibre-optic cable, the servo card and the Pulsecoder wiring instead. For SRVO-058, FANUC suggests powering up with CRF8 on the amplifier disconnected: if the alarm goes away, the robot connection cable (RP1) or the Pulsecoder cable inside the arm is shorted to ground. For F4, see power cuts out right after power-on.
A fuse has blown on a process I/O board, and the rack and slot numbers in the message tell you which board. Every process I/O board has a single FUSE1 protecting its +24E. The visible sign is a lit ALM-2 / FALM LED on a JA or JB board, or a lit ALM1 / FALM LED on an MA or MB board. A blown fuse on a JA / JB board can also stop the robot with I/O alarms such as IMSTP.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus (A and B cabinet) | FUSE1 | 2.0 A | A60L-0001-0046#2.0 | Upper left corner of the board |
| R-30iB / Plus and Mate / Mate Plus | FUSE1 | 1.0 A | A60L-0001-0046#1.0 | Right end, below the FALM LED |
| R-30iB / Plus and Mate / Mate Plus | FUSE1 | 1.0 A | A60L-0001-0046#1.0 | Right end, mid-height |
FUSE1 is at the upper left corner of the board. The JB board has it in the same place.FUSE1 is at the right end, below the FALM LED.FUSE1 is at the right end, mid-height. The ALM1 and FALM LEDs are at the upper left.Before replacing the fuse, check the cables and the peripheral equipment connected to that I/O board for a short. If it blows again, replace the process I/O board.
This fuse is not on the main controller boards. It is on the brake unit of an auxiliary axis (the number in brackets is the servo amplifier the brake unit is connected to), or on the local stop unit if the cell has one. A defective brake cable is the usual cause, so FANUC's instruction is to replace the brake cable first, then the fuse. Like SRVO-214, this alarm can also come from an auxiliary-axis amplifier set to amplifier type 1 instead of 2.
The brake unit is documented in FANUC's auxiliary-axis maintenance manual, and its layout depends on the option fitted, so we do not draw it here. Send us a photo of the unit and we will point to the fuse.
The compact R-30iB Compact Plus and the Mini Plus (the CRX controller) name their fuse alarms differently. We do not have drawings for these two yet; the table tells you which fuse and board.
| Alarm | Fuse | Compact Plus | Mini Plus | Rating | What to check |
|---|---|---|---|---|---|
SRVO-227 Amplifier fuse blown | FUSE9 | Main board | Main board | 2 A | Feeds 24 V to the servo amplifier and the fan, so a fan alarm usually comes with it. FANUC suggests the fan unit first. |
SRVO-228 RI/O fuse blown | FUSE4 | Interface unit | Main board | 2.0 A | End-effector 24 V shorted to 0 V: check the robot connection cable and the end-effector cable. |
SRVO-229 SDI fuse blown | FUSE2 | Interface unit | Main board | 1.0 A | 24SDI shorted to 0 V: check the peripheral-device cables. |
Every other Compact Plus and Mini Plus fuse is listed in the reference tables below.
No alarm, but something stopped working
Some fuses do not raise an alarm of their own, because what they feed is what would display it. These are the symptoms to look for.
On an R-30iB / R-30iB Plus a dark pendant points to FUSE3 on the E-stop board, which feeds the teach pendant. A damaged pendant cable is the most common reason it blows, so check the cable first, then the pendant, then the board.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus, A-cabinet | FUSE3 | 1 A | A60L-0001-0290#LM10C | Left of centre, right next to CRP34 |
| R-30iB / R-30iB Plus, B-cabinet | FUSE3 | 1 A | A60L-0001-0290#LM10C | Middle of the board, right of CRT27 |
| R-30iB Mate | FUSE3 | 1 A | A60L-0001-0290#LM10C | Lower middle, just left of the 24T LED, near CRS36 |
| R-30iB Mate | FUSE5 | 5 A | A60L-0001-0290#LM50C | Top edge, right of FUSE4, above the 24V3 LED |
| R-30iB Mate Plus | FUSE3 | 1 A | A60L-0001-0290#LM10C | Lower middle, just left of the 24T LED, near CRS36 |
| R-30iB Mate Plus | FUSE5 | 5 A | A60L-0001-0290#LM50C | Top edge, right of FUSE4, above the 24V3 LED |
| R-30iB Mate Plus | FUSE8 | 0.3 A | A60L-0001-0175#0.3A | Right edge, at the top (200 V side: lock out and prove zero volts first) |
FUSE3 is left of centre, right next to CRP34.FUSE3 is in the middle of the board, right of CRT27, with FUSE1 just below it.FUSE3 is in the lower middle, just left of the 24T LED, which lights red when it blows.On a Mate / Mate Plus, read the LEDs
- Red
24TLED, screen dark:FUSE3(pendant supply). Check the pendant cable, the E-stop-board-to-main-board cable onCRS40, and the pendant. - Red
24V3LED, pendant cannot be operated:FUSE5(5 A, +24 V to the main board). - Mate Plus only: pendant dead and the 7-segment display on the main board shows 7 (if it blew at power-on, the green
LEDG2andLEDG4status LEDs on the main board are lit):FUSE8, the 0.3 A fuse in the 200 V power-monitor circuit. FANUC's instruction here is to replace the E-stop board, not the fuse.FUSE8is on the 200 V side: lock out the supply and prove zero volts before touching it or the board. - Compact Plus: interface unit
FUSE1(pendant), or main boardFUSE8with the redFU24V1LED. Mini Plus: main boardFUSE6(pendant), main boardFUSE8with the redFU24V1LED, or input boardFUSE1with a 7 on the 7-segment display. The input board carries the incoming mains: lock out the supply and prove zero volts before touching that fuse.
On an R-30iB / R-30iB Plus, if the green PIL LED on the power supply unit stays off and the controller will not turn on, check F1 on the power supply unit, and on controllers built with an AC reactor, F2 on the reactor's connector panel. Both are on the AC input side. Lock out the supply and prove zero volts before touching them.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus (A and B cabinet) | F1 | 8.0 A | A60L-0001-0450#8R0 | Near the top of the front edge |
| R-30iB / R-30iB Plus (A and B cabinet) | F2 | 7.5 A | A60L-0001-0245#GP75 | Single holder at the top of the panel, above the IN / OUT terminals |
F1 is near the top of the front edge.F2 is the single fuse holder at the top, above the IN / OUT terminal blocks.Before replacing either fuse, check the fans, boards and cables connected to CP2 and CP3 on the power supply unit for a short circuit. If the new fuse blows again, replace the power supply unit.
If the controller turns itself off immediately after power-on and the red ALM LED on the power supply unit lights, F4 (+24 V) has blown. Press the OFF button once to clear the ALM LED.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / R-30iB Plus (A and B cabinet) | F4 | 7.5 A | A60L-0001-0046#7.5 | Mid-height, the lower of the F3 / F4 pair, just above the green PIL LED |
F4 is the lower fuse of the mid-height pair, just above the green PIL LED. The red ALM LED is further down.Before replacing F4, work through the boards, units, servo amplifier and cables on +24 V (your maintenance manual's power-supply diagram lists them) and replace whatever is shorted. If the new fuse still blows, replace the power supply unit.
Controllers with built-in vision supply +24E to the camera through a small fuse on the main board: FU1 on the R-30iB Plus and FUSE9 on the Mate Plus. Neither raises an alarm of its own; the camera simply goes dead.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB Plus | FU1 | 0.5 A before general version 06B · 1.0 A since general version 07C · not stated for versions in between | not printed in the manual | Very bottom of the front edge, below the servo card |
| R-30iB Mate Plus | FUSE9 | 1.0 A | A60L-0001-0290#LM10 | Middle of the connector row, beside the coax vision connector |
FU1 is at the very bottom of the front edge, below the servo card. FANUC prints no part number for it; its rating depends on the board's general version (0.5 A before general version 06B · 1.0 A since general version 07C · not stated for versions in between). Check your board's general version; if it falls between those, or you cannot tell, ask us rather than copying the fuse you removed, which may itself be wrong.FUSE9 is in the middle of the connector row, beside the coax vision connector.FANUC's procedure for both: check the camera's +24E for a ground fault, then the camera cables and related parts; if those are fine, the next step is to replace the main board (take a full backup first). FANUC does not document swapping this fuse on its own, so if the camera wiring checks out, talk to us before going further. On a Compact Plus or Mini Plus the vision fuse is FUSE7 on the main board.
On a Mate / Mate Plus the door and rear cabinet fans run on 200 VAC through FUSE6 and FUSE7 on the E-stop board, so a stopped fan, and the fan alarm that follows, can be one of these. They carry 200 VAC: lock out the supply and prove zero volts first. Check the fan cable, then the fan unit, then the board.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB Mate | FUSE6 | 3.2 A | A60L-0001-0175#3.2A | Right edge, mid-height, the upper of the two |
| R-30iB Mate | FUSE7 | 3.2 A | A60L-0001-0175#3.2A | Right edge, mid-height, directly below FUSE6 |
| R-30iB Mate Plus | FUSE6 | 3.2 A | A60L-0001-0175#3.2A | Right edge, just left of FUSE7 |
| R-30iB Mate Plus | FUSE7 | 3.2 A | A60L-0001-0175#3.2A | Right edge, below FUSE8 |
FUSE6 and FUSE7 are stacked on the right edge at mid-height, FUSE6 above FUSE7.FUSE7 is on the right edge below FUSE8, with FUSE6 just to its left.The Mate and Mate Plus E-stop board has a red LED beside each of its main 24 V fuses, which makes them the fastest fuses on this page to diagnose. The 24EXT, 24V2 and 24V3 LEDs sit directly below FUSE2, FUSE4 and FUSE5 on the top edge; the 24T LED is just right of FUSE3.
| Red LED | Fuse | Rating | What you see |
|---|---|---|---|
24EXT | FUSE2 | 1 A | SRVO-007 that will not reset (details) |
24T | FUSE3 | 1 A | Pendant screen dark (details) |
24V2 | FUSE4 | 2 A | An alarm on one of the inputs that trigger an emergency stop. Check the connections on the E-stop board terminal strip, then the board-to-board cables. |
24V3 | FUSE5 | 5 A | Pendant cannot be operated (details) |
FUSE2, FUSE4 and FUSE5 along the top edge with their LEDs below, FUSE3 in the lower middle, FUSE6 and FUSE7 on the right edge.FUSE8 (0.3 A, 200 V power monitor) at the top of the right edge; it is on the 200 V side, so lock out and prove zero volts before touching it.Controllers driving a FANUC CR-series collaborative robot have a sensor I/F unit with one 2 A fuse for its internal supply. When it blows, the red FUSE LED on the unit lights. Check the cables and peripheral devices connected to the unit, then replace the fuse; if it blows again, replace the unit.
| Controller | Fuse | Rating | FANUC part no. | Where on the board |
|---|---|---|---|---|
| R-30iB / Plus and Mate / Mate Plus driving a CR cobot | FUSE | 2 A | A60L-0001-0290#LM20 | Lower right panel, directly above the red FUSE LED |
FUSE LED.Where each board sits in the cabinet
Before you can find a fuse, you have to find its board. These are the three cabinet layouts this guide covers, seen with the door open.
Fuse reference: every fuse, every rating
Every fuse in the controllers this guide covers, with the FANUC part number exactly as printed in the maintenance manual. Order by part number: two fuses with the same rating can differ in type and speed.
| Board / unit | Fuse | Rating | FANUC part no. | Feeds |
|---|---|---|---|---|
| Power supply unit (PSU) | F1 | 8.0 A | A60L-0001-0450#8R0 | AC input |
| AC reactor connector panel | F2 | 7.5 A | A60L-0001-0245#GP75 | AC input (AC-reactor builds) |
| Power supply unit (PSU) | F3 | 7.5 A | A60L-0001-0046#7.5 | +24E supply |
| Power supply unit (PSU) | F4 | 7.5 A | A60L-0001-0046#7.5 | +24V supply |
| Main board (R-30iB Plus) | FU1 | 0.5 A before general version 06B · 1.0 A since general version 07C · not stated for versions in between | not printed in the manual | +24E output for vision |
| 6-axis servo amplifier | FS1 | 3.2 A | A60L-0001-0290#LM32C | Amplifier control-circuit power |
| 6-axis servo amplifier | FS2 | 3.2 A | A60L-0001-0290#LM32C | 24 V to end effector, XROT, XHBK |
| 6-axis servo amplifier | FS3 | 3.2 A | A60L-0001-0290#LM32C | 24 V to regenerative (discharge) resistor |
| E-stop board, A-cabinet | FUSE1 | 1 A | A60L-0001-0290#LM10C | Internal power-supply circuit |
| E-stop board, A-cabinet | FUSE2 | 1 A | A60L-0001-0290#LM10C | +24EXT emergency-stop line |
| E-stop board, A-cabinet | FUSE3 | 1 A | A60L-0001-0290#LM10C | Teach pendant power |
| E-stop board, B-cabinet | FUSE1 | 1 A | A60L-0001-0290#LM10C | Internal power-supply circuit |
| E-stop board, B-cabinet | FUSE2 | 1 A | A60L-0001-0290#LM10C | +24EXT emergency-stop line |
| E-stop board, B-cabinet | FUSE3 | 1 A | A60L-0001-0290#LM10C | Teach pendant power |
| E-stop board, B-cabinet | FUSE4 | 1 A | A60L-0001-0290#LM10C | SFDI (B-cabinet only) |
| Process I/O board JA / JB | FUSE1 | 2.0 A | A60L-0001-0046#2.0 | +24E (boards JA and JB) |
| Process I/O board MA | FUSE1 | 1.0 A | A60L-0001-0046#1.0 | +24E |
| Process I/O board MB | FUSE1 | 1.0 A | A60L-0001-0046#1.0 | +24E |
| Additional safety I/O board | FU1 | 1 A | A60L-0001-0290#LM10C | +24V to safety inputs (SFDI) |
| Additional safety I/O board | FU2 | 3.2 A | A60L-0001-0290#LM32C | +24V to safety outputs (SFDO) |
| Cobot sensor I/F unit | FUSE | 2 A | A60L-0001-0290#LM20 | Sensor I/F internal supply |
| Board / unit | Fuse | Rating | FANUC part no. | Feeds |
|---|---|---|---|---|
| Main board (Mate) | FUSE1 | 1.0 A | A60L-0001-0290#LM10 | +24V peripheral I/O (24SDI) |
| Main board (Mate Plus) | FUSE1 | 1.0 A | A60L-0001-0290#LM10 | +24V peripheral I/O (24SDI) |
| Main board (Mate Plus) | FUSE9 | 1.0 A | A60L-0001-0290#LM10 | +24E output for vision |
| E-stop board (Mate) | FUSE2 | 1 A | A60L-0001-0290#LM10C | Emergency-stop circuit |
| E-stop board (Mate) | FUSE3 | 1 A | A60L-0001-0290#LM10C | Teach pendant power |
| E-stop board (Mate) | FUSE4 | 2 A | A60L-0001-0290#LM20C | +24V |
| E-stop board (Mate) | FUSE5 | 5 A | A60L-0001-0290#LM50C | +24V to the main board |
| E-stop board (Mate) | FUSE6 | 3.2 A | A60L-0001-0175#3.2A | 200 VAC to a cabinet fan |
| E-stop board (Mate) | FUSE7 | 3.2 A | A60L-0001-0175#3.2A | 200 VAC to a cabinet fan |
| E-stop board (Mate Plus) | FUSE2 | 1 A | A60L-0001-0290#LM10C | Emergency-stop circuit |
| E-stop board (Mate Plus) | FUSE3 | 1 A | A60L-0001-0290#LM10C | Teach pendant power |
| E-stop board (Mate Plus) | FUSE4 | 2 A | A60L-0001-0290#LM20C | +24V |
| E-stop board (Mate Plus) | FUSE5 | 5 A | A60L-0001-0290#LM50C | +24V to the main board |
| E-stop board (Mate Plus) | FUSE6 | 3.2 A | A60L-0001-0175#3.2A | 200 VAC to a cabinet fan |
| E-stop board (Mate Plus) | FUSE7 | 3.2 A | A60L-0001-0175#3.2A | 200 VAC to a cabinet fan |
| E-stop board (Mate Plus) | FUSE8 | 0.3 A | A60L-0001-0175#0.3A | 200 V power-monitor circuit |
| Board / unit | Fuse | Rating | FANUC part no. | Feeds |
|---|---|---|---|---|
| Main board (Compact Plus) | FUSE7 | 1 A | A60L-0001-0290#LM10C | +24E output for vision |
| Main board (Compact Plus) | FUSE8 | 6.3 A | A60L-0001-0046#6.3 | +24V of the main board |
| Main board (Compact Plus) | FUSE9 | 2 A | A60L-0001-0290#LM20C | +24V to the servo amplifier unit |
| Interface unit (Compact Plus) | FUSE1 | 1.0 A | A60L-0001-0290#LM10C | Teach pendant +24V |
| Interface unit (Compact Plus) | FUSE2 | 1.0 A | A60L-0001-0290#LM10C | +24V peripheral I/O (24SDI) |
| Interface unit (Compact Plus) | FUSE3 | 1.0 A | A60L-0001-0290#LM10C | Emergency-stop circuit |
| Interface unit (Compact Plus) | FUSE4 | 2.0 A | A60L-0001-0290#LM20C | +24V to the end effector (EE) |
| Interface unit (Compact Plus) | FUSE5 | 2.0 A | A60L-0001-0290#LM20C | +5V to the Pulsecoders |
| Interface unit (Compact Plus) | FUSE6 | 1.0 A | A60L-0001-0290#LM10C | +24V to the brakes |
| Board / unit | Fuse | Rating | FANUC part no. | Feeds |
|---|---|---|---|---|
| Input board (Mini Plus) | FUSE1 | 0.3 A | A60L-0001-0175#0.3A | Mains power-monitoring circuit (AC side) |
| Main board (Mini Plus) | FUSE2 | 1 A | A60L-0001-0290#LM10C | +24V peripheral I/O (24SDI) |
| Main board (Mini Plus) | FUSE3 | 1 A | A60L-0001-0290#LM10C | Emergency-stop circuit |
| Main board (Mini Plus) | FUSE4 | 2 A | A60L-0001-0290#LM20C | +24V to the robot end effector |
| Main board (Mini Plus) | FUSE5 | 2 A | A60L-0001-0290#LM20C | +5V to the Pulsecoders |
| Main board (Mini Plus) | FUSE6 | 1 A | A60L-0001-0290#LM10C | Teach pendant +24V |
| Main board (Mini Plus) | FUSE7 | 1 A | A60L-0001-0290#LM10C | +24E output for vision |
| Main board (Mini Plus) | FUSE8 | 6.3 A | A60L-0001-0046#6.3 | +24V of the main board |
| Main board (Mini Plus) | FUSE9 | 2 A | A60L-0001-0290#LM20C | +24V to the servo amplifier board |
| Main board (Mini Plus) | FUSE10 | 1 A | A60L-0001-0290#LM10C | +24V to the cobot sensor |
| Main board (Mini Plus) | FUSE11 | 5 A | A60L-0001-0290#LM50C | +30V to the tool I/F |
The Mini Plus manual lists part numbers without ratings, so the Mini Plus ratings above are those printed for the same FANUC part numbers in the Compact Plus and Mate manuals.
How to replace a fuse safely

Step by step
- Record the alarm. Photograph the alarm screen and the alarm history before you power down. It is the first thing we will ask for.
- Power down safely. Lock out and tag the supply disconnect that feeds the controller (not just the controller breaker), then prove zero volts where you will work. At the servo amplifier, wait for the
V4LED to go out and confirm the DC link is below 50 V. - Find the fuse with the drawing for your controller, and check the designator printed on the board before you pull anything.
- Pull it straight out with a fuse puller or fine pliers. Do not lever it against neighbouring parts.
- Test it out of circuit: continuity or ohms across its two ends. An open circuit means it has blown.
- Find the cause using the checks in the section for your alarm. Disconnect what the fuse feeds and measure for a short to 0 V or ground.
- Fit the new fuse: same FANUC part number, fully seated.
- Power up and watch. If it blows again straight away, stop. The fault is still there, and feeding it more fuses will not find it.
- Reset and test the alarm, the E-stop chain, the pendant and the tooling before handing the robot back to production.
Still stuck? Send us the alarm
If the fuse keeps blowing, the board needs replacing, or you would rather not open the cabinet at all, contact Xpert Robotics. Send a photo of the alarm screen and the controller nameplate, and we will tell you which fuse or board you need and whether it is a job for a site visit.
Disclaimer
This guide is provided for general information only, to help qualified technicians find their way around FANUC controllers. It is not official FANUC documentation, and it does not replace the FANUC maintenance manual, FANUC training, or the advice of a qualified service engineer.
Please note
- Check the manual first. Hardware differs between controller versions, board revisions and options. Always verify the fuse, its location, rating and part number against the official FANUC manual for your exact controller before you replace anything.
- No warranty. We work hard to keep this page accurate, but it may contain errors or omissions and may be out of date. It is provided "as is", without any warranty of any kind.
- Your responsibility. Any work you do based on this page is done at your own risk and under your own responsibility. Electrical work on a controller must be carried out only by qualified personnel, following FANUC's instructions and your site's safety procedures.
- No liability. To the fullest extent permitted by law, Xpert Robotics is not liable for any injury, damage, downtime, lost production or other loss, direct or indirect, arising from the use of, or reliance on, the information on this page.
- Not affiliated with FANUC. Xpert Robotics is an independent company. This page is not written, reviewed or endorsed by FANUC Corporation.
FANUC is a trademark of FANUC Corporation. The drawings on this page are original illustrations by Xpert Robotics, based on the published maintenance documentation; they show positions, not dimensions, and are not to scale. Keep the official FANUC maintenance manual for your controller at hand: it is the authority on your exact hardware revision.