SRVO-214, SRVO-213, SRVO-217, SRVO-219, SRVO-220 and more: find your alarm, see exactly which fuse blew and where it sits on the board, with original diagrams, ratings and FANUC part numbers for R-30iB, R-30iB Plus and R-30iB Mate / Mate Plus controllers.

A blown fuse inside a FANUC robot controller almost always announces itself in one of two ways: a specific alarm on the teach pendant, or one specific thing that suddenly stops working. This page connects each of those symptoms to the exact fuse behind it: which board it sits on, where that board lives in the cabinet, where the fuse is on the board, its rating, and its FANUC part number.

It covers the R-30iB, R-30iB Plus (A-cabinet and B-cabinet) and R-30iB Mate / Mate Plus controllers, with the fuse alarms of the Compact Plus and Mini Plus (CRX) as a bonus. Every board drawing is an original Xpert Robotics diagram with the fuse in question highlighted in yellow. Tap a drawing to open it full-size.

Warning: A controller holds mains voltage and stored energy even when switched off. Read Safety first before you open the cabinet.

NOTE

This guide is a starting point, not a replacement for the FANUC manual. Always confirm the fuse, its position, rating and part number in the official FANUC maintenance manual for your controller before you work on it. Xpert Robotics accepts no liability for errors on this page or for how it is used: see the full disclaimer.

Find your alarm

Type the alarm number from the pendant (for example 214) or a symptom, or filter by controller, then tap the card. Every section has its own link: use the link button next to a heading to send it to whoever is standing at the robot. "Mate" means R-30iB Mate and Mate Plus unless a card says otherwise.

How to use this page

Four steps

  • Read the alarm exactly. Open the alarm screen (MENU → ALARM, then HIST for the history) and note the code, the text and anything in brackets. In SRVO-214 6ch amplifier fuse blown (R:1), the R:1 tells you which servo amplifier.
  • Know your controller. Check the nameplate: R-30iB or R-30iB Plus (in an A-cabinet or the larger B-cabinet), or R-30iB Mate / Mate Plus. The same fuse can sit in a different place on each.
  • Jump to the alarm. Each section shows the fuse highlighted on its board, with its rating and part number, and what to check before you replace it.
  • Fix the cause, then the fuse. A fuse that blew once will blow again if the short is still there.

Safety first: read before you open the cabinet

NOTE

A robot controller holds mains voltage and stored DC energy. Only a qualified electrical technician should open it. If you are not sure, stop and contact us: a wrong fuse, or a wire bridged across a fuse holder, can destroy a board worth far more than a service visit, or silently disable a safety circuit.

Before you touch anything

  • Isolate upstream, lock and tag. Switching off the controller's own breaker is not isolation: its input terminals and the incoming supply cable stay live. Lock out the disconnect that feeds the controller. Several fuses on this page sit on the AC side (PSU F1, AC-reactor F2, Mate / Mate Plus FUSE6 / FUSE7, Mate Plus FUSE8, Mini Plus input board FUSE1): prove zero volts at the fuse holder itself before you touch them.
  • Servo amplifier: wait for V4. Before touching the 6-axis amplifier, the V4 LED must be off, and a DC voltmeter on the screw just right of V4 must read below 50 V. If the LED is lit or the DC link is 50 V or more, do not touch the amplifier or its cables. This check covers the amplifier only, not the rest of the cabinet.
  • ESD. Wear a grounded wrist strap and hold boards by their edges.
  • Same part, same rating. Replace a fuse only with the same FANUC part number, or at minimum the identical rating and type. Never fit a higher rating.
  • Never bypass. Never bridge a fuse with wire, and never jumper an E-stop, fence or safety circuit to "test" the robot.
  • Find the short first. A fuse blows for a reason. Fit a new one without finding it and it blows again, or the fault moves upstream to something more expensive.
  • Back up before swapping boards. Before replacing a main board or an E-stop unit, take a full controller backup (an image backup where possible).

Fuse alarms, one by one

SRVO-214 6ch amplifier fuse blown (R:n): Fuse FS2 or FS3 on the servo amplifier

Fuse FS2 or FS3 has blown on 6-axis servo amplifier number n (R:1 is the first amplifier). Both are 3.2 A fuses on the amplifier's control board. The alarms that appear together with SRVO-214 tell you which one:

Which fuse?

  • With SRVO-006 Hand broken and SRVO-005 Robot overtravel: it is FS2. FS2 feeds the 24 V that goes up the robot to the end effector, plus the hand-broken (XHBK) and overtravel (XROT) signals, so when it blows those two alarms come with it.
  • With SRVO-043 DCAL alarm: it is FS3, which feeds 24 V to the regenerative (discharge) resistor.
  • With neither, and an auxiliary axis on the system: check the setup before the hardware. SRVO-214 also appears when an axis driven by an auxiliary (αiSV) amplifier is set to amplifier type 1 (6-axis amplifier) instead of 2.
Servo amplifier fuses behind SRVO-214
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / Plus and Mate / Mate PlusFS23.2 AA60L-0001-0290#LM32CBottom of the column
R-30iB / Plus and Mate / Mate PlusFS33.2 AA60L-0001-0290#LM32CMiddle of the column, between FS1 and FS2
Diagram of the FANUC 6-axis servo amplifier with fuses FS2 and FS3 highlighted in the fuse column at the upper right of the control board
The 6-axis servo amplifier, identical on R-30iB, R-30iB Plus and Mate / Mate Plus. The three fuses form a column at the upper right of the control board: FS1 on top, FS3 in the middle, FS2 at the bottom. FS3 being in the middle catches people out.

Where the amplifier is: on the left of the back panel in an A-cabinet, in the upper right of a B-cabinet, and in the centre of the back panel in a Mate. See the cabinet maps.

Before you replace FS2 or FS3

  • FS2: look for a ground fault on the end-effector 24 V (+24VF): the gripper or tool wiring, its valves and sensors, and the end-effector connector on the arm. Then check the robot connection cable and the cables inside the arm. On an M-3iA, also check the optional fan motor inside the robot.
  • FS3: check the regenerative resistor and its cable, and replace the resistor if it is faulty. FANUC also lists a ground fault in an auxiliary-axis amplifier as a possible cause.
  • Then replace the fuse. If the new one blows straight away, the fault is still there. FANUC's next step is to replace the amplifier.

SRVO-213 E-STOP Board FUSE2 blown: FUSE2 on the E-stop board

FUSE2 on the emergency-stop board protects the +24EXT line: the 24 V that runs out to your external E-stop buttons, fence and door switches, and back. The same alarm also appears when the fuse is fine but there is simply no 24 V between EXT24V and EXT0V, on terminal strip TBOP14 in an A-cabinet or TBOP10 in a B-cabinet. It often arrives together with SRVO-001, SRVO-004 or SRVO-007.

E-stop board FUSE2 behind SRVO-213
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus, A-cabinetFUSE21 AA60L-0001-0290#LM10CBottom edge, between CRMB2 and the TBOP14 terminal strip
R-30iB / R-30iB Plus, B-cabinetFUSE21 AA60L-0001-0290#LM10CLeft edge, between TBOP11 and TBOP10, above CRMA92
Diagram of the R-30iB A-cabinet emergency-stop board with FUSE2 highlighted on the bottom edge between CRMB2 and TBOP14
A-cabinet E-stop board: FUSE2 is on the bottom edge, between connector CRMB2 and the TBOP14 terminal strip.
Diagram of the R-30iB B-cabinet emergency-stop board with FUSE2 highlighted on the left edge between TBOP11 and TBOP10
B-cabinet E-stop board (tall, portrait): FUSE2 is on the left edge, between the TBOP11 and TBOP10 terminal strips, above CRMA92.

Before you replace FUSE2

  • Measure 24 V between EXT24V and EXT0V. If the cell does not use an external 24 V supply, check the jumpers between EXT24V and INT24V and between EXT0V and INT0V.
  • If FENCE, SVOFF or EXEMG are wired, one of them may be shorted to 0 V or to ground. Check those cables first: a pinched fence-switch cable is a classic cause.
  • Still blowing? FANUC's order is: the operator-panel cable (CRT27), then the E-stop board, then the teach pendant cable, then the pendant itself.
NOTE

On a Mate / Mate Plus, a blown E-stop FUSE2 usually shows as SRVO-007 with a red 24EXT LED; see SRVO-007. Also, on older Mate, Mate Plus and Compact Plus software (Mate 7DC3/43, 7DC2/33, 7DD0/16 or earlier; Mate Plus and Compact Plus 7DF1/12 or earlier), a blown fuse on the additional safety I/O board is wrongly reported as SRVO-213. If FUSE2 is fine on such a controller, go to SRVO-219.

SRVO-007 External emergency stops: FUSE2 on the Mate / Mate Plus E-stop board

On a Mate or Mate Plus, if SRVO-007 will not reset even though every external E-stop is released, and the red 24EXT LED on the E-stop board is lit, FUSE2 (the emergency-stop circuit fuse) has blown.

E-stop board FUSE2 behind SRVO-007
ControllerFuseRatingFANUC part no.Where on the board
R-30iB MateFUSE21 AA60L-0001-0290#LM10CTop edge, first from the left, above the 24EXT LED
R-30iB Mate PlusFUSE21 AA60L-0001-0290#LM10CTop edge, first from the left, above the 24EXT LED
Diagram of the R-30iB Mate Plus emergency-stop board with FUSE2 highlighted at the top-left edge above the 24EXT LED
Mate Plus E-stop board: FUSE2 is the first fuse from the left on the top edge, directly above the 24EXT LED. It sits in the same place on the R-30iB Mate board.

Before you replace FUSE2

  • Measure 24 V between EXT24V and EXT0V on TBOP19. If no external supply is used, check the EXT24V–INT24V and EXT0V–INT0V jumpers.
  • Check the 24EXT emergency-stop wiring for a short or a ground fault.
  • Still blowing? Replace the E-stop board, then check the teach pendant.

SRVO-217 E-STOP Board not found · PRIO-091 E-Stop PCB comm error: FUSE1 on the E-stop board, or F3 on the power supply

The main board cannot see the E-stop board. On an R-30iB / R-30iB Plus two fuses cause it: FUSE1 on the E-stop board, which feeds the board's own power-supply circuit, or F3 on the power supply unit, which supplies +24E. This alarm also appears when an additional safe I/O device is missing, so a fuse is likely but not the only cause.

Fuses behind SRVO-217 and PRIO-091
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus, A-cabinetFUSE11 AA60L-0001-0290#LM10CUpper right, just left of CNMC6 and below CRRA12
R-30iB / R-30iB Plus, B-cabinetFUSE11 AA60L-0001-0290#LM10CMiddle of the board, just below FUSE3
R-30iB / R-30iB Plus (A and B cabinet)F37.5 AA60L-0001-0046#7.5Mid-height, the upper of the F3 / F4 pair, above the green PIL LED
Diagram of the R-30iB A-cabinet emergency-stop board with FUSE1 highlighted at the upper right, left of CNMC6
A-cabinet E-stop board: FUSE1 is at the upper right, just left of CNMC6 and below CRRA12.
Diagram of the R-30iB B-cabinet emergency-stop board with FUSE1 highlighted in the middle, just below FUSE3
B-cabinet E-stop board: FUSE1 is in the middle of the board, just below FUSE3.
Diagram of the R-30iB power supply unit with fuse F3 highlighted at mid-height, above F4 and the green PIL LED
Power supply unit: F3 is the upper fuse of the pair at mid-height, with F4 just below it and the green PIL LED under both.

Before you replace FUSE1 or F3

  • FUSE1: check the cable between the E-stop board and the main board. If the fuse is fine and the cable is good, FANUC's next steps are the E-stop unit, then (after a full backup) the main board.
  • F3: +24E feeds many boards, units and cables in the cabinet. Work through everything on +24E (the power-supply diagram in your maintenance manual lists it) and replace the faulty part. Then replace F3; if it still blows, replace the power supply unit.

SRVO-220 SDI fuse blown: FUSE1 on the Mate / Mate Plus main board

FUSE1 on the Mate / Mate Plus main board protects the +24 V the controller supplies to your peripheral I/O (24SDI). The usual cause is 24SDI shorted to 0 V somewhere in the peripheral-device wiring: a pinched cable, a failed sensor, a miswired terminal.

Main board FUSE1 behind SRVO-220
ControllerFuseRatingFANUC part no.Where on the board
R-30iB MateFUSE11.0 AA60L-0001-0290#LM10Connector edge, bottom-left corner of the connector row
R-30iB Mate PlusFUSE11.0 AA60L-0001-0290#LM10Connector edge, bottom-left corner of the connector row
Diagram of the R-30iB Mate main board connector edge with FUSE1 highlighted at the bottom-left corner of the connector row
R-30iB Mate main board, which is mounted on the cabinet door: FUSE1 is at the bottom-left corner of the connector row; CRS40 is further right, just before the two Ethernet ports.
Diagram of the R-30iB Mate Plus main board connector edge with FUSE1 highlighted at the bottom-left corner
R-30iB Mate Plus main board: FUSE1 is in the same bottom-left corner. The second fuse in the row, FUSE9, is for vision; see camera has no power.

Before you replace FUSE1

  • Check the peripheral-device cables for damage and replace any that are faulty.
  • Disconnect CRS40 and fit a new fuse. If it still blows with CRS40 disconnected, the fault is on the main board: take a full image backup, then replace the board.
  • If it only blows with CRS40 connected, FANUC's next suspects are the cable from the E-stop unit to the servo amplifier, the cable from the main board to the E-stop unit, the E-stop unit and the servo amplifier.

SRVO-219 Safety I/O brd fuse1 / fuse2 blown: FU1 or FU2 on the additional safety I/O board

A fuse has blown on the optional additional safety I/O board: fuse1 is FU1 (24 V to the safety inputs, SFDI) and fuse2 is FU2 (24 V to the safety outputs, SFDO). When more than one safe I/O device is fitted, the number at the end of the message, such as (1), tells you which device; it matches the DCS Safe I/O device menu.

Safety I/O board fuses behind SRVO-219
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / Plus and Mate / Mate PlusFU11 AA60L-0001-0290#LM10CLower right, left of the JGP connector; the left one of the pair
R-30iB / Plus and Mate / Mate PlusFU23.2 AA60L-0001-0290#LM32CLower right, between FU1 and the JGP connector
Diagram of the additional safety I/O board with fuses FU1 and FU2 highlighted side by side at the lower right, left of the JGP connector
Additional safety I/O board: FU1 and FU2 sit side by side at the lower right, just left of the tall JGP connector. FU1 is the left one.

Before you replace FU1 or FU2

  • Check the cable on CRMA90 for a ground fault and replace it if needed. That cable carries the safety inputs and outputs these fuses feed.
  • Replace the fuse. If it blows again, replace the additional safety I/O board.

SRVO-348 DCS MCC OFF alarm: FUSE4 on the B-cabinet E-stop board

SRVO-348 means the controller commanded the main contactor (MCC) off and it did not drop out. It has several causes. FANUC's first check is whatever is wired to CRMA74 on the E-stop unit; the second, on an R-30iB / Plus B-cabinet, is FUSE4 on the E-stop board, which protects the SFDI safety inputs. The A-cabinet board has no FUSE4.

E-stop board FUSE4 behind SRVO-348
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus, B-cabinetFUSE41 AA60L-0001-0290#LM10CUpper left, at the top of the TBOP11 terminal strip
Diagram of the R-30iB B-cabinet emergency-stop board with FUSE4 highlighted at the upper left, at the top of the TBOP11 terminal strip
B-cabinet E-stop board: FUSE4 is at the upper left, at the top of the TBOP11 terminal strip.

Before you replace FUSE4

  • Check the SFDI wiring and connections for a short, then the operator-panel cable (CRT27).
  • Replace the fuse. If it blows again, FANUC's next step is the E-stop unit.

SRVO-057 FSSB disconnect · SRVO-058 FSSB init error: All amplifier LEDs dark: F4, then FS1

FSSB is the fibre-optic link between the main board and the servo amplifier. FSSB alarms have many causes, but if every LED on the servo amplifier is dark the amplifier has no control power, and there are two fuses to check: F4 on the power supply unit, which FANUC checks first, then FS1 on the amplifier, which generates the amplifier's control-circuit power.

Fuses behind SRVO-057 / SRVO-058 with a dark amplifier
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus (A and B cabinet)F47.5 AA60L-0001-0046#7.5Mid-height, the lower of the F3 / F4 pair, just above the green PIL LED
R-30iB / Plus and Mate / Mate PlusFS13.2 AA60L-0001-0290#LM32CTop of the fuse column, upper-right edge of the control PCB
Diagram of the FANUC 6-axis servo amplifier with fuse FS1 highlighted at the top of the fuse column
FS1 is the top fuse of the column on the servo amplifier's control board.
NOTE

FS1 is the exception to "fix the cause, replace the fuse". FANUC's instruction for a blown FS1 is to replace the 6-axis servo amplifier, fuse included: FS1 feeds the amplifier's own internal control circuit, so when it blows the fault is almost always inside the amplifier. Contact us for a replacement or repaired unit.

If the amplifier LEDs are lit, FS1 is not your problem. Check the fibre-optic cable, the servo card and the Pulsecoder wiring instead. For SRVO-058, FANUC suggests powering up with CRF8 on the amplifier disconnected: if the alarm goes away, the robot connection cable (RP1) or the Pulsecoder cable inside the arm is shorted to ground. For F4, see power cuts out right after power-on.

PRIO-093 Fuse blown (Rack, Slot): FUSE1 on a process I/O board

A fuse has blown on a process I/O board, and the rack and slot numbers in the message tell you which board. Every process I/O board has a single FUSE1 protecting its +24E. The visible sign is a lit ALM-2 / FALM LED on a JA or JB board, or a lit ALM1 / FALM LED on an MA or MB board. A blown fuse on a JA / JB board can also stop the robot with I/O alarms such as IMSTP.

Process I/O board fuses behind PRIO-093
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus (A and B cabinet)FUSE12.0 AA60L-0001-0046#2.0Upper left corner of the board
R-30iB / Plus and Mate / Mate PlusFUSE11.0 AA60L-0001-0046#1.0Right end, below the FALM LED
R-30iB / Plus and Mate / Mate PlusFUSE11.0 AA60L-0001-0046#1.0Right end, mid-height
Diagram of process I/O board JA with FUSE1 highlighted at the upper left corner
Process I/O board JA: FUSE1 is at the upper left corner of the board. The JB board has it in the same place.
Diagram of process I/O board MA with FUSE1 highlighted at the right end, below the FALM LED
Process I/O board MA: FUSE1 is at the right end, below the FALM LED.
Diagram of process I/O board MB with FUSE1 highlighted at the right end, mid-height
Process I/O board MB: FUSE1 is at the right end, mid-height. The ALM1 and FALM LEDs are at the upper left.

Before replacing the fuse, check the cables and the peripheral equipment connected to that I/O board for a short. If it blows again, replace the process I/O board.

SRVO-215 Brake Unit fuse blown (R:n): The fuse in the auxiliary-axis brake unit

This fuse is not on the main controller boards. It is on the brake unit of an auxiliary axis (the number in brackets is the servo amplifier the brake unit is connected to), or on the local stop unit if the cell has one. A defective brake cable is the usual cause, so FANUC's instruction is to replace the brake cable first, then the fuse. Like SRVO-214, this alarm can also come from an auxiliary-axis amplifier set to amplifier type 1 instead of 2.

The brake unit is documented in FANUC's auxiliary-axis maintenance manual, and its layout depends on the option fitted, so we do not draw it here. Send us a photo of the unit and we will point to the fuse.

SRVO-227 · SRVO-228 · SRVO-229: Compact Plus and Mini Plus fuse alarms

The compact R-30iB Compact Plus and the Mini Plus (the CRX controller) name their fuse alarms differently. We do not have drawings for these two yet; the table tells you which fuse and board.

Compact Plus and Mini Plus fuse alarms
AlarmFuseCompact PlusMini PlusRatingWhat to check
SRVO-227 Amplifier fuse blownFUSE9Main boardMain board2 AFeeds 24 V to the servo amplifier and the fan, so a fan alarm usually comes with it. FANUC suggests the fan unit first.
SRVO-228 RI/O fuse blownFUSE4Interface unitMain board2.0 AEnd-effector 24 V shorted to 0 V: check the robot connection cable and the end-effector cable.
SRVO-229 SDI fuse blownFUSE2Interface unitMain board1.0 A24SDI shorted to 0 V: check the peripheral-device cables.

Every other Compact Plus and Mini Plus fuse is listed in the reference tables below.

No alarm, but something stopped working

Some fuses do not raise an alarm of their own, because what they feed is what would display it. These are the symptoms to look for.

The teach pendant screen is dark

On an R-30iB / R-30iB Plus a dark pendant points to FUSE3 on the E-stop board, which feeds the teach pendant. A damaged pendant cable is the most common reason it blows, so check the cable first, then the pendant, then the board.

Fuses behind a dark teach pendant
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus, A-cabinetFUSE31 AA60L-0001-0290#LM10CLeft of centre, right next to CRP34
R-30iB / R-30iB Plus, B-cabinetFUSE31 AA60L-0001-0290#LM10CMiddle of the board, right of CRT27
R-30iB MateFUSE31 AA60L-0001-0290#LM10CLower middle, just left of the 24T LED, near CRS36
R-30iB MateFUSE55 AA60L-0001-0290#LM50CTop edge, right of FUSE4, above the 24V3 LED
R-30iB Mate PlusFUSE31 AA60L-0001-0290#LM10CLower middle, just left of the 24T LED, near CRS36
R-30iB Mate PlusFUSE55 AA60L-0001-0290#LM50CTop edge, right of FUSE4, above the 24V3 LED
R-30iB Mate PlusFUSE80.3 AA60L-0001-0175#0.3ARight edge, at the top (200 V side: lock out and prove zero volts first)
Diagram of the R-30iB A-cabinet emergency-stop board with FUSE3 highlighted left of centre next to CRP34
A-cabinet E-stop board: FUSE3 is left of centre, right next to CRP34.
Diagram of the R-30iB B-cabinet emergency-stop board with FUSE3 highlighted in the middle, right of CRT27
B-cabinet E-stop board: FUSE3 is in the middle of the board, right of CRT27, with FUSE1 just below it.
Diagram of the R-30iB Mate Plus emergency-stop board with FUSE3 highlighted in the lower middle, left of the 24T LED
Mate / Mate Plus E-stop board: FUSE3 is in the lower middle, just left of the 24T LED, which lights red when it blows.

On a Mate / Mate Plus, read the LEDs

  • Red 24T LED, screen dark: FUSE3 (pendant supply). Check the pendant cable, the E-stop-board-to-main-board cable on CRS40, and the pendant.
  • Red 24V3 LED, pendant cannot be operated: FUSE5 (5 A, +24 V to the main board).
  • Mate Plus only: pendant dead and the 7-segment display on the main board shows 7 (if it blew at power-on, the green LEDG2 and LEDG4 status LEDs on the main board are lit): FUSE8, the 0.3 A fuse in the 200 V power-monitor circuit. FANUC's instruction here is to replace the E-stop board, not the fuse. FUSE8 is on the 200 V side: lock out the supply and prove zero volts before touching it or the board.
  • Compact Plus: interface unit FUSE1 (pendant), or main board FUSE8 with the red FU24V1 LED. Mini Plus: main board FUSE6 (pendant), main board FUSE8 with the red FU24V1 LED, or input board FUSE1 with a 7 on the 7-segment display. The input board carries the incoming mains: lock out the supply and prove zero volts before touching that fuse.

The controller will not power on

On an R-30iB / R-30iB Plus, if the green PIL LED on the power supply unit stays off and the controller will not turn on, check F1 on the power supply unit, and on controllers built with an AC reactor, F2 on the reactor's connector panel. Both are on the AC input side. Lock out the supply and prove zero volts before touching them.

Fuses behind a controller that will not power on
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus (A and B cabinet)F18.0 AA60L-0001-0450#8R0Near the top of the front edge
R-30iB / R-30iB Plus (A and B cabinet)F27.5 AA60L-0001-0245#GP75Single holder at the top of the panel, above the IN / OUT terminals
Diagram of the R-30iB power supply unit with fuse F1 highlighted near the top of the front edge
Power supply unit, the narrow unit in the backplane rack: F1 is near the top of the front edge.
Diagram of the AC reactor connector panel with fuse F2 highlighted at the top, above the IN and OUT terminals
AC reactor connector panel (only on controllers built with an AC reactor): F2 is the single fuse holder at the top, above the IN / OUT terminal blocks.

Before replacing either fuse, check the fans, boards and cables connected to CP2 and CP3 on the power supply unit for a short circuit. If the new fuse blows again, replace the power supply unit.

Power cuts out right after you switch on

If the controller turns itself off immediately after power-on and the red ALM LED on the power supply unit lights, F4 (+24 V) has blown. Press the OFF button once to clear the ALM LED.

Power supply fuse F4
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / R-30iB Plus (A and B cabinet)F47.5 AA60L-0001-0046#7.5Mid-height, the lower of the F3 / F4 pair, just above the green PIL LED
Diagram of the R-30iB power supply unit with fuse F4 highlighted at mid-height, just above the green PIL LED
Power supply unit: F4 is the lower fuse of the mid-height pair, just above the green PIL LED. The red ALM LED is further down.

Before replacing F4, work through the boards, units, servo amplifier and cables on +24 V (your maintenance manual's power-supply diagram lists them) and replace whatever is shorted. If the new fuse still blows, replace the power supply unit.

The vision camera has no power

Controllers with built-in vision supply +24E to the camera through a small fuse on the main board: FU1 on the R-30iB Plus and FUSE9 on the Mate Plus. Neither raises an alarm of its own; the camera simply goes dead.

Vision supply fuses
ControllerFuseRatingFANUC part no.Where on the board
R-30iB PlusFU10.5 A before general version 06B · 1.0 A since general version 07C · not stated for versions in betweennot printed in the manualVery bottom of the front edge, below the servo card
R-30iB Mate PlusFUSE91.0 AA60L-0001-0290#LM10Middle of the connector row, beside the coax vision connector
Diagram of the R-30iB Plus main board with fuse FU1 highlighted at the very bottom of the front edge
R-30iB Plus main board, in the backplane rack: FU1 is at the very bottom of the front edge, below the servo card. FANUC prints no part number for it; its rating depends on the board's general version (0.5 A before general version 06B · 1.0 A since general version 07C · not stated for versions in between). Check your board's general version; if it falls between those, or you cannot tell, ask us rather than copying the fuse you removed, which may itself be wrong.
Diagram of the R-30iB Mate Plus main board connector edge with FUSE9 highlighted in the middle, beside the vision connector
R-30iB Mate Plus main board: FUSE9 is in the middle of the connector row, beside the coax vision connector.

FANUC's procedure for both: check the camera's +24E for a ground fault, then the camera cables and related parts; if those are fine, the next step is to replace the main board (take a full backup first). FANUC does not document swapping this fuse on its own, so if the camera wiring checks out, talk to us before going further. On a Compact Plus or Mini Plus the vision fuse is FUSE7 on the main board.

A cabinet fan has stopped (Mate / Mate Plus)

On a Mate / Mate Plus the door and rear cabinet fans run on 200 VAC through FUSE6 and FUSE7 on the E-stop board, so a stopped fan, and the fan alarm that follows, can be one of these. They carry 200 VAC: lock out the supply and prove zero volts first. Check the fan cable, then the fan unit, then the board.

Fan fuses on the Mate E-stop board
ControllerFuseRatingFANUC part no.Where on the board
R-30iB MateFUSE63.2 AA60L-0001-0175#3.2ARight edge, mid-height, the upper of the two
R-30iB MateFUSE73.2 AA60L-0001-0175#3.2ARight edge, mid-height, directly below FUSE6
R-30iB Mate PlusFUSE63.2 AA60L-0001-0175#3.2ARight edge, just left of FUSE7
R-30iB Mate PlusFUSE73.2 AA60L-0001-0175#3.2ARight edge, below FUSE8
Diagram of the R-30iB Mate emergency-stop board with fan fuses FUSE6 and FUSE7 highlighted on the right edge
R-30iB Mate E-stop board: FUSE6 and FUSE7 are stacked on the right edge at mid-height, FUSE6 above FUSE7.
Diagram of the R-30iB Mate Plus emergency-stop board with fan fuses FUSE6 and FUSE7 highlighted on the right edge below FUSE8
R-30iB Mate Plus E-stop board: FUSE7 is on the right edge below FUSE8, with FUSE6 just to its left.

A red LED is lit on the Mate / Mate Plus E-stop board

The Mate and Mate Plus E-stop board has a red LED beside each of its main 24 V fuses, which makes them the fastest fuses on this page to diagnose. The 24EXT, 24V2 and 24V3 LEDs sit directly below FUSE2, FUSE4 and FUSE5 on the top edge; the 24T LED is just right of FUSE3.

Mate / Mate Plus E-stop board: red LED to fuse
Red LEDFuseRatingWhat you see
24EXTFUSE21 ASRVO-007 that will not reset (details)
24TFUSE31 APendant screen dark (details)
24V2FUSE42 AAn alarm on one of the inputs that trigger an emergency stop. Check the connections on the E-stop board terminal strip, then the board-to-board cables.
24V3FUSE55 APendant cannot be operated (details)
Diagram of the R-30iB Mate emergency-stop board showing every fuse and LED
R-30iB Mate E-stop board, all fuses: FUSE2, FUSE4 and FUSE5 along the top edge with their LEDs below, FUSE3 in the lower middle, FUSE6 and FUSE7 on the right edge.
Diagram of the R-30iB Mate Plus emergency-stop board showing every fuse and LED
R-30iB Mate Plus E-stop board, all fuses. It adds FUSE8 (0.3 A, 200 V power monitor) at the top of the right edge; it is on the 200 V side, so lock out and prove zero volts before touching it.

Red FUSE LED on the cobot sensor interface unit

Controllers driving a FANUC CR-series collaborative robot have a sensor I/F unit with one 2 A fuse for its internal supply. When it blows, the red FUSE LED on the unit lights. Check the cables and peripheral devices connected to the unit, then replace the fuse; if it blows again, replace the unit.

Cobot sensor I/F unit fuse
ControllerFuseRatingFANUC part no.Where on the board
R-30iB / Plus and Mate / Mate Plus driving a CR cobotFUSE2 AA60L-0001-0290#LM20Lower right panel, directly above the red FUSE LED
Diagram of the cobot sensor interface unit with its fuse highlighted in the lower right panel, above the red FUSE LED
Sensor I/F unit: the fuse holder is in the lower right panel, directly above the red FUSE LED.

Where each board sits in the cabinet

Before you can find a fuse, you have to find its board. These are the three cabinet layouts this guide covers, seen with the door open.

Map of the R-30iB / R-30iB Plus A-cabinet showing the servo amplifier, power supply unit, main board, E-stop board and AC reactor
A-cabinet: the servo amplifier is on the left of the back panel, and the backplane rack to its right holds the power supply unit and the main board. The E-stop board runs across the top of the back panel, above the rack, and the AC reactor (where fitted) is at the top left, next to the breaker.
Map of the R-30iB / R-30iB Plus B-cabinet showing the servo amplifier in the upper right and the power supply, main board and E-stop board in the lower section
B-cabinet: the servo amplifier is in the upper right. The power supply unit, main board and E-stop board are in the lower section, with the E-stop board at the lower right. The AC reactor is on the right wall.
Map of the R-30iB Mate / Mate Plus cabinet showing the main board on the door, the servo amplifier in the centre and the E-stop board on the right
Mate / Mate Plus: the main board is mounted on the door (on the left when the door is open), the 6-axis servo amplifier is in the centre of the back panel, and the E-stop board is on the right side, below the breaker.

Fuse reference: every fuse, every rating

Every fuse in the controllers this guide covers, with the FANUC part number exactly as printed in the maintenance manual. Order by part number: two fuses with the same rating can differ in type and speed.

R-30iB / R-30iB Plus (A- and B-cabinet)
Board / unitFuseRatingFANUC part no.Feeds
Power supply unit (PSU)F18.0 AA60L-0001-0450#8R0AC input
AC reactor connector panelF27.5 AA60L-0001-0245#GP75AC input (AC-reactor builds)
Power supply unit (PSU)F37.5 AA60L-0001-0046#7.5+24E supply
Power supply unit (PSU)F47.5 AA60L-0001-0046#7.5+24V supply
Main board (R-30iB Plus)FU10.5 A before general version 06B · 1.0 A since general version 07C · not stated for versions in betweennot printed in the manual+24E output for vision
6-axis servo amplifierFS13.2 AA60L-0001-0290#LM32CAmplifier control-circuit power
6-axis servo amplifierFS23.2 AA60L-0001-0290#LM32C24 V to end effector, XROT, XHBK
6-axis servo amplifierFS33.2 AA60L-0001-0290#LM32C24 V to regenerative (discharge) resistor
E-stop board, A-cabinetFUSE11 AA60L-0001-0290#LM10CInternal power-supply circuit
E-stop board, A-cabinetFUSE21 AA60L-0001-0290#LM10C+24EXT emergency-stop line
E-stop board, A-cabinetFUSE31 AA60L-0001-0290#LM10CTeach pendant power
E-stop board, B-cabinetFUSE11 AA60L-0001-0290#LM10CInternal power-supply circuit
E-stop board, B-cabinetFUSE21 AA60L-0001-0290#LM10C+24EXT emergency-stop line
E-stop board, B-cabinetFUSE31 AA60L-0001-0290#LM10CTeach pendant power
E-stop board, B-cabinetFUSE41 AA60L-0001-0290#LM10CSFDI (B-cabinet only)
Process I/O board JA / JBFUSE12.0 AA60L-0001-0046#2.0+24E (boards JA and JB)
Process I/O board MAFUSE11.0 AA60L-0001-0046#1.0+24E
Process I/O board MBFUSE11.0 AA60L-0001-0046#1.0+24E
Additional safety I/O boardFU11 AA60L-0001-0290#LM10C+24V to safety inputs (SFDI)
Additional safety I/O boardFU23.2 AA60L-0001-0290#LM32C+24V to safety outputs (SFDO)
Cobot sensor I/F unitFUSE2 AA60L-0001-0290#LM20Sensor I/F internal supply
R-30iB Mate / Mate Plus (servo amplifier, process I/O MA / MB, safety I/O and cobot unit as in the table above)
Board / unitFuseRatingFANUC part no.Feeds
Main board (Mate)FUSE11.0 AA60L-0001-0290#LM10+24V peripheral I/O (24SDI)
Main board (Mate Plus)FUSE11.0 AA60L-0001-0290#LM10+24V peripheral I/O (24SDI)
Main board (Mate Plus)FUSE91.0 AA60L-0001-0290#LM10+24E output for vision
E-stop board (Mate)FUSE21 AA60L-0001-0290#LM10CEmergency-stop circuit
E-stop board (Mate)FUSE31 AA60L-0001-0290#LM10CTeach pendant power
E-stop board (Mate)FUSE42 AA60L-0001-0290#LM20C+24V
E-stop board (Mate)FUSE55 AA60L-0001-0290#LM50C+24V to the main board
E-stop board (Mate)FUSE63.2 AA60L-0001-0175#3.2A200 VAC to a cabinet fan
E-stop board (Mate)FUSE73.2 AA60L-0001-0175#3.2A200 VAC to a cabinet fan
E-stop board (Mate Plus)FUSE21 AA60L-0001-0290#LM10CEmergency-stop circuit
E-stop board (Mate Plus)FUSE31 AA60L-0001-0290#LM10CTeach pendant power
E-stop board (Mate Plus)FUSE42 AA60L-0001-0290#LM20C+24V
E-stop board (Mate Plus)FUSE55 AA60L-0001-0290#LM50C+24V to the main board
E-stop board (Mate Plus)FUSE63.2 AA60L-0001-0175#3.2A200 VAC to a cabinet fan
E-stop board (Mate Plus)FUSE73.2 AA60L-0001-0175#3.2A200 VAC to a cabinet fan
E-stop board (Mate Plus)FUSE80.3 AA60L-0001-0175#0.3A200 V power-monitor circuit
R-30iB Compact Plus
Board / unitFuseRatingFANUC part no.Feeds
Main board (Compact Plus)FUSE71 AA60L-0001-0290#LM10C+24E output for vision
Main board (Compact Plus)FUSE86.3 AA60L-0001-0046#6.3+24V of the main board
Main board (Compact Plus)FUSE92 AA60L-0001-0290#LM20C+24V to the servo amplifier unit
Interface unit (Compact Plus)FUSE11.0 AA60L-0001-0290#LM10CTeach pendant +24V
Interface unit (Compact Plus)FUSE21.0 AA60L-0001-0290#LM10C+24V peripheral I/O (24SDI)
Interface unit (Compact Plus)FUSE31.0 AA60L-0001-0290#LM10CEmergency-stop circuit
Interface unit (Compact Plus)FUSE42.0 AA60L-0001-0290#LM20C+24V to the end effector (EE)
Interface unit (Compact Plus)FUSE52.0 AA60L-0001-0290#LM20C+5V to the Pulsecoders
Interface unit (Compact Plus)FUSE61.0 AA60L-0001-0290#LM10C+24V to the brakes
R-30iB Mini Plus (CRX)
Board / unitFuseRatingFANUC part no.Feeds
Input board (Mini Plus)FUSE10.3 AA60L-0001-0175#0.3AMains power-monitoring circuit (AC side)
Main board (Mini Plus)FUSE21 AA60L-0001-0290#LM10C+24V peripheral I/O (24SDI)
Main board (Mini Plus)FUSE31 AA60L-0001-0290#LM10CEmergency-stop circuit
Main board (Mini Plus)FUSE42 AA60L-0001-0290#LM20C+24V to the robot end effector
Main board (Mini Plus)FUSE52 AA60L-0001-0290#LM20C+5V to the Pulsecoders
Main board (Mini Plus)FUSE61 AA60L-0001-0290#LM10CTeach pendant +24V
Main board (Mini Plus)FUSE71 AA60L-0001-0290#LM10C+24E output for vision
Main board (Mini Plus)FUSE86.3 AA60L-0001-0046#6.3+24V of the main board
Main board (Mini Plus)FUSE92 AA60L-0001-0290#LM20C+24V to the servo amplifier board
Main board (Mini Plus)FUSE101 AA60L-0001-0290#LM10C+24V to the cobot sensor
Main board (Mini Plus)FUSE115 AA60L-0001-0290#LM50C+30V to the tool I/F

The Mini Plus manual lists part numbers without ratings, so the Mini Plus ratings above are those printed for the same FANUC part numbers in the Compact Plus and Mate manuals.

How to replace a fuse safely

Gloved hands testing a removed glass fuse with multimeter probes on both end caps, with an empty fuse holder on a circuit board behind
Test a fuse out of the circuit, one probe on each end cap, with the meter on continuity or ohms. (Illustrative photo: FANUC board fuses are small plug-in types, but the test is the same.)

Step by step

  • Record the alarm. Photograph the alarm screen and the alarm history before you power down. It is the first thing we will ask for.
  • Power down safely. Lock out and tag the supply disconnect that feeds the controller (not just the controller breaker), then prove zero volts where you will work. At the servo amplifier, wait for the V4 LED to go out and confirm the DC link is below 50 V.
  • Find the fuse with the drawing for your controller, and check the designator printed on the board before you pull anything.
  • Pull it straight out with a fuse puller or fine pliers. Do not lever it against neighbouring parts.
  • Test it out of circuit: continuity or ohms across its two ends. An open circuit means it has blown.
  • Find the cause using the checks in the section for your alarm. Disconnect what the fuse feeds and measure for a short to 0 V or ground.
  • Fit the new fuse: same FANUC part number, fully seated.
  • Power up and watch. If it blows again straight away, stop. The fault is still there, and feeding it more fuses will not find it.
  • Reset and test the alarm, the E-stop chain, the pendant and the tooling before handing the robot back to production.

Still stuck? Send us the alarm

If the fuse keeps blowing, the board needs replacing, or you would rather not open the cabinet at all, contact Xpert Robotics. Send a photo of the alarm screen and the controller nameplate, and we will tell you which fuse or board you need and whether it is a job for a site visit.

Disclaimer

This guide is provided for general information only, to help qualified technicians find their way around FANUC controllers. It is not official FANUC documentation, and it does not replace the FANUC maintenance manual, FANUC training, or the advice of a qualified service engineer.

Please note

  • Check the manual first. Hardware differs between controller versions, board revisions and options. Always verify the fuse, its location, rating and part number against the official FANUC manual for your exact controller before you replace anything.
  • No warranty. We work hard to keep this page accurate, but it may contain errors or omissions and may be out of date. It is provided "as is", without any warranty of any kind.
  • Your responsibility. Any work you do based on this page is done at your own risk and under your own responsibility. Electrical work on a controller must be carried out only by qualified personnel, following FANUC's instructions and your site's safety procedures.
  • No liability. To the fullest extent permitted by law, Xpert Robotics is not liable for any injury, damage, downtime, lost production or other loss, direct or indirect, arising from the use of, or reliance on, the information on this page.
  • Not affiliated with FANUC. Xpert Robotics is an independent company. This page is not written, reviewed or endorsed by FANUC Corporation.

FANUC is a trademark of FANUC Corporation. The drawings on this page are original illustrations by Xpert Robotics, based on the published maintenance documentation; they show positions, not dimensions, and are not to scale. Keep the official FANUC maintenance manual for your controller at hand: it is the authority on your exact hardware revision.

FANUC blown fuseSRVO-214SRVO-213SRVO-217SRVO-219SRVO-220